Wall-mounted
Products
Our range. Your brand.

What it is
Same 39 g body, same two readings, same 100-per-carton pack. The formaldehyde channel moves from a semiconductor element to an electrochemical cell — selective where the semiconductor is not.
A semiconductor element responds to formaldehyde and to a dozen other things. An electrochemical cell responds to formaldehyde. When the number is going to be quoted to a landlord or a client, that distinction is the whole product.
The broader VOC channel remains, so the pair still tells a complete story about a room's materials.
About an hour to charge, 39 g.
Same enclosure and packing as AK18D — the upgrade tier without a second carton spec.
OEM & ODM
Instant estimate

Wall-mounted